Warranty: | 1 Year |
---|---|
Certification: | CE |
Brand: | Siron |
Code | 12 | 24 | 48 | 60 | 110 | 220 |
Voltage | 12V | 24V | 48V | 60V | 110V | 220V |
Model | P191-12000 -12 | P191-12000 -24 | P191-12000 -48 | P191-12000 -60 | P191-12000 -110 | P191-12000 -220 | |
Output characteristic | Dc voltage | 12V | 24V | 48V | 60V | 100V | 220V |
Rated current | 600V | 500A | 250A | 200A | 109A | 54A | |
Current range | 0~600A | 0~500A | 0~250A | 0~200A | 0~109A | 0~54A | |
Rated power | 12000W | 12000W | 12000W | 12000W | 12000W | 12000W | |
Ripple | 500mW | 500mW | 600mW | 600mW | 1000mW | 1500mW | |
Voltage regulation range | 6~15V | 12~24V | 24~48V | 30~60V | 55~110V | 110~220V | |
Voltage accuracy | ±1.0% | ||||||
Linear adjustment rate | ±1.0% | ||||||
Load adjustment rate | ±1.0% | ||||||
Start & rise time | 1500ms,700ms/230VAC (full load) | ||||||
Input characteristic | Voltage range | 95~190VAC(50% full-load output current)/195~265VDC(100% full-load output current) | |||||
Frequency range | 45~65Hz | ||||||
Efficiency factor | PF≥0.99/230VAC(full load) | ||||||
Power | 87% | 90% | 92% | 92% | 92.5% | 93% | |
Alternating current | <110A | ||||||
Leakage current | <3.0mA/240VAC |
Protection | Short-circuit | Upon entering constant current with voltage < 10% of rated value, output shuts down and locks after 1s. Recovery via restart. | |||||
Over temperature | The output will be shut down, and it will automatically recover upon temperature decrease or after a restart. | ||||||
Overcurrent | Users can configure the overcurrent threshold; upon triggering, the output shuts down after 5s delay. Recovery via restart. | ||||||
Overvoltage | Overvoltage setting: User-definable; Output voltage shutdown on trip. Reset via restart. | ||||||
Feature | Output voltage regulation | 0~13.2V | 0~26.4V | 0~52.8V | 0~66V | 0~121V | 0~242V |
Output constant current adjustment | 0~600A | 0~500A | 0~250V | 0~200A | 0~109A | 0~54A | |
485 communication | MODBUS Communication Protocol | ||||||
Isolating auxiliary power supply | 12V, 0.5A (Needs To Be Customized) | ||||||
Output remote control switch | The device powers on by default and shuts down when a high level (5-12V) is applied. (Needs To Be Customized) | ||||||
Alarm output | The power normal indication is provided via a dry contact rated for ≤36V and 0.1A. | ||||||
Environmental characteristics | Operating temperature | -20~+60℃ | |||||
Working humidity | -20~90%RH No condensation | ||||||
Store temperature/humidity | -40℃~85℃,10~95%RH, No condensation | ||||||
Vibration resistance | 10 to 500Hz, 2G for 10 minutes per cycle, 60 minutes for each of X, Y, Z axes | ||||||
afetyregulation | Withstand voltage | I/P-0/P:2KVAC ; I/P-FG:2KVAC ; 0/P-FG:0.5KVAC | |||||
Insulation impedance | Input and Output:100Mhms/500VDC/25℃/70%RH | ||||||
Product size | 455×345×251mm (L×W×H) | ||||||
Package | 20kg |